Web pages, dashboards, documents, images and live streams full screen on one or more monitors, managed from a web panel.
WallStatus turns a Windows PC or a Mac connected to one or more screens into a video wall: at power-on it shows the chosen pages and content full screen, refreshes them on its own and is managed from a web panel.
wallstatus.bytenooks.com with downloads, manuals and XML language files in every language.http://<address>:8088/Monitor01, /Monitor02…; at /Monitor all monitors in rotation.| Windows PC | Mac | |
|---|---|---|
| System | Windows 11 (Windows 10 too) | macOS 11 Big Sur or later, Apple Silicon or Intel |
| Browser | Microsoft Edge, already included in Windows | Google Chrome or Microsoft Edge (Safari cannot be used) |
| Installation | No additional software to install. WallStatus is a single file and does not require administrator rights. | |
| Network | Connection to the websites to be shown. To manage it from another PC, the two computers must be on the same network. | |
WallStatus uses the browser already on the computer (Edge or Chrome) with a separate profile dedicated to the wall: it does not touch the user's bookmarks, passwords or history. It opens a window without bars for each monitor and makes it full screen on the right screen.
The Windows package is the file WallStatus-1.20.0-Windows.zip.
| File | What it is for |
|---|---|
| Installa WallStatus.cmd | Installs the program for the current user, creates the shortcuts and enables automatic start |
| Torna al wall.cmd | At the end of a Remote Desktop session, returns the session to the wall screens (chapter 20) |
| Aggiorna WallStatus.cmd | Updates an installed version keeping everything, with a backup copy (see below) |
| Disinstalla WallStatus.cmd | Removes the program, shortcuts, automatic start and (optionally) the data |
| WallStatus.exe | The program. It can also be run directly, without installation |
| Manuale WallStatus.pdf | This manual |
The installation copies the program to %LOCALAPPDATA%\Programs\WallStatus and creates:
Alternatively, copy WallStatus.exe to any folder, even on a USB stick, and run it with a double-click. The configuration is saved in the data subfolder next to the program. Automatic start is enabled from the panel (Settings → Startup).
Updating keeps the configuration, users, monitors, content, uploaded documents, saved passwords and the automatic start setting. Before the program is replaced, an automatic backup copy is made.
WallStatus-1.20.0-Windows.zip) to the wall PC → right-click → Extract All…. There is no need to close WallStatus first: the script does it.Close WallStatus (Ctrl+Alt+Shift+Q), then copy WallStatus-precedente.exe from the backup folder in place of %LOCALAPPDATA%\Programs\WallStatus\WallStatus.exe (renaming it WallStatus.exe) and, if needed, also config.json into the data folder. Restart WallStatus. The same path is shown at the end of the script.
Running Installa WallStatus.cmd from the new version again also works (it still keeps the data, but asks again about automatic start and does not make the backup copy). If WallStatus was used without installation (portable), just replace WallStatus.exe in its folder and run it.
In any case, if you start a new version while a different one is running, the previous version is closed and replaced automatically (with the same version, on the other hand, only the panel opens).
As long as network access is disabled, WallStatus does not accept connections from outside and the firewall does not ask anything. When you enable management from other PCs (chapter 18) Windows may ask for permission: select Private networks and confirm with Allow.
The Mac package is the file WallStatus-1.20.0-Mac.dmg. It works on Macs with Apple processors (M1–M4 and later) and Intel.
Google Chrome (google.com/chrome) or Microsoft Edge must be installed on the Mac. WallStatus does not work with Safari.
This happens when the file was downloaded from the internet or received via AirDrop/e-mail. The app is not damaged: open Terminal (Applications → Utilities), paste this command, then press Return:
xattr -cr /Applications/WallStatus.app
Then open the app again.
In the panel open Settings → Startup and enable Start WallStatus when the PC is switched on. WallStatus will start every time the user signs in. macOS may show a "Background Items Added" notification: this is normal.
Website passwords are encrypted with a key saved in the macOS Keychain (entry WallStatus-secret-key). If macOS asks for access to the Keychain the first time a password is saved, choose Always Allow.
xattr -cr /Applications/WallStatus.app again.In the DMG (and in the package folder) there is Disinstalla WallStatus.command: double-click it (the first time right-click → Open) and Terminal opens with a menu: 1 closes WallStatus and its browser (even if not responding), 2 uninstalls everything (app, automatic start, data and Keychain key, after you type SI), 3 uninstalls keeping the data. From Terminal: --chiudi, --rimuovi or --prova to see what it would do without touching anything.
Manually:
For a wall that switches on and works with nobody in front of it, it is worth adjusting a few operating system settings. These are recommendations, not requirements.
Automatic user sign-in
Settings → Accounts → Sign-in options: turn off "For improved security, only allow Windows Hello sign-in for Microsoft accounts on this device". Then press Win+R, type netplwiz, untick "Users must enter a user name and password to use this computer" and enter the user's password.
Power
Settings → System → Power: Turn off my screen and Make my device sleep set to Never. WallStatus prevents the screen from turning off anyway while it is running.
Updates
Settings → Windows Update → Advanced options → Active hours: set them to the hours when the wall is in use, so restarts happen outside those hours.
Notifications
Turn on Do not disturb to avoid pop-ups over the pages.
Automatic sign-in
System Settings → Users & Groups → Automatically log in as: choose the wall user. Not available if FileVault is on.
Multiple monitors: separate Spaces
System Settings → Desktop & Dock → Mission Control section: "Displays have separate Spaces" must be on (it is the default). Without this option macOS can show only one window full screen.
Power
System Settings → Lock Screen: Turn display off when inactive set to Never; on a MacBook also Battery → Options → Prevent automatic sleeping.
Notifications
Turn on Focus → Do Not Disturb.
All configuration is done from the web panel. Changes are applied to the monitors immediately, without restarting anything.
| From where | How |
|---|---|
| From the wall PC | Press Ctrl+Shift+A while the displays are visible, or open http://127.0.0.1:8088/admin in the browser |
| Without displays | The WallStatus – solo pannello shortcut in the Start menu (Windows) |
| From another PC | http://<wall-address>:8088/admin, only after enabling network access (chapter 18) |
The panel is always protected by username and password, even when you open it from the wall PC. The first time you open it, from the wall PC, the Welcome to WallStatus screen appears:


admin or your name).Until the account exists, the panel cannot be reached from other computers. If you forget the password, see chapter 21.
| Element | Function |
|---|---|
| Status indicator | Green dot: displays running (with the number of open windows). Grey: stopped. Red: error, with the explanation under the header. |
| Identify | Shows each monitor's name and physical screen number on it for 6 seconds |
| Reload | Reloads all pages and repositions the windows |
| Start / Stop displays | Opens or closes the full-screen windows. The panel stays available even when the displays are stopped. |
| Web view | Opens /Monitor: all monitors live, in rotation, in a browser tab (chapter 16) |
| Mobile view | Opens the monitor view designed for smartphones (chapter 16) |
| user · Sign out | Shows the signed-in user and closes the session |
| Tabs | Monitors, Messages, Content, Servers, Bandwidth, Map, Traceroute, Scheduling, Audio, Users, Appearance, Settings, Log (recent events, useful in case of problems) and Help (this manual, chapter 27). Each user sees only the tabs they have permission for. |
1. Create the content (Content tab) → 2. assign it to the monitors (Monitors tab) → 3. choose the layout of each monitor.
A monitor in WallStatus is a display area linked to a physical screen. Up to 6 physical ones can be configured (one per screen) and, in addition, as many virtual ones as you like, visible only from the web link and on mobile.
Choose which screen to show the monitor on. Screens are numbered from left to right; disconnected ones appear as (not connected) and the monitor is shown as soon as the screen is connected and detected. Two active monitors cannot use the same screen: the panel flags this with a yellow warning.
| Icon | Layout | What it shows |
|---|---|---|
| Single | The first active content item in the list, full screen | |
| ⟳ | Timed rotation | All active content, one at a time full screen. The time is set in Change content item every (seconds); it can be paused and skipped forwards or backwards |
| ⇥ | Manual rotation | All active content, one at a time full screen, but it moves to the next one only on command: key, remote or ⏮ ⏭ buttons (see below) |
| 2 side by side | Two content items, left and right | |
| 2 stacked | Two content items, top and bottom (ideal for portrait monitors) | |
| 1 large + 2 | One large main content item and two smaller ones on the right | |
| 2×2 grid | Four content items | |
| 3×2 grid | Six content items |
On monitors in Timed rotation or Manual rotation with at least two content items, the rotation controls appear under “On air”, with the position (e.g. 2/5) and the time left until the next change:


/Monitor01…), at the top right, for users with the Displays permission.| Where | Controls |
|---|---|
| Panel, Monitors tab | ⏮, ⏸ Pause / ▶ Resume, ⏭ buttons on each monitor's card (Displays permission) |
Web view /Monitor01, /Reception… | ⏮ ⏸ ⏭ buttons at the top right (Displays permission). They control the wall monitor, not just your own view. |
| Wall keyboard | Ctrl+Shift+N next, Ctrl+Shift+P previous, Ctrl+Shift+Space (or S) pause / resume |
| Presentation remote | PgDn / PgUp (the keys sent by common slide “clickers”) move to the next / previous content item |
| Media keys | ⏭ ⏮ ⏯ on USB/Bluetooth keyboards and remotes |
Reception → http://<address>:8088/Reception (see below).
Who can see it (administrators only): with the switch on, the monitor is visible in the web view and on mobile to all users with the View streams permission (according to the monitors chosen in their account). Turning it off lets you choose the users who can see it: for example a virtual monitor for each customer, each visible only to its own user.
Content audio (videos, live streams, cameras with Audio on):
/Monitor01… presses Listen here and hears the audio in their own browser (chapter 16);A virtual monitor works like a physical monitor (layouts, rotation, content, websites with login, documents) but does not take up a PC screen: it is watched only from the web view (chapter 16) and the mobile view. It is useful, for example, for preparing a screen dedicated to a room or department that opens it from a smart TV or a PC, without adding monitors to the wall.

Each monitor, physical or virtual, opens in the web view with its number (/Monitor01, /Monitor02…, according to the order in the Monitors tab). With Name in the link you can give it a custom address, easier to remember and which does not change if you reorder the monitors:
| Name in the link | Monitor addresses |
|---|---|
Reception | http://<address>:8088/Reception (also /reception, /Monitor/Reception and the number /Monitor03) |
sala-riunioni | http://<address>:8088/sala-riunioni |
Letters, digits, - and _ are allowed (up to 40 characters, no spaces); upper and lower case make no difference. Each name can be used by only one monitor, and names reserved by the program are not allowed (admin, mobile, api, Monitor, Monitor01…). Leaving the field empty keeps only the numbered address.
In grid layouts websites are shown in tiles. WallStatus removes the "this site cannot be displayed in a frame" block, but some websites with login do not keep the session inside a tile. The Single and Rotation layouts instead show the page full screen like a normal browser and work with any website.
The Content tab lists everything that can be shown on the monitors.
| Type | Address to enter | Examples |
|---|---|---|
| Web page | Full address, with https://, or the path of an HTML page in a file or a network folder (file://…, \\server\…, C:\…) | Grafana, Power BI, Zabbix, PRTG, status pages, intranet, monitoring pages saved on a file server |
| Image | Upload a file (jpg, png, gif, webp, svg) or enter the address of an online image | Floor plans, notices, logos, webcam snapshots |
| Online video | Link to the YouTube, Facebook or Vimeo video or live stream | Live events, news channels, corporate videos: they start on their own full screen |
| HLS stream | Address of the .m3u8 stream | IP cameras, encoders, streaming platforms |
| Video | Uploaded mp4/webm file or address | Corporate videos in a loop |
| Teams | Link to the event or meeting | Town halls, live events, meetings (see chapter 9) |
| X account | Account address (https://x.com/MSFT365Status) or @name | Service status accounts: recent posts as full-screen cards (see below) |
| RSS feed | Address of the RSS or Atom feed | News, alerts, service status: they scroll as a ticker (chapter 11) |
| Documents | Uploaded files, web addresses (one per line) and/or a folder on the wall PC | Shift rotas, procedures, PDF reports, Excel sheets, presentations: page by page (chapter 10) |
Web pages, RSS feeds and X accounts can stay hidden while everything is fine and appear on their own when they report something. In the content item form, Show only when there are problems box → Watched.

| Content item | When it is shown |
|---|---|
| Web page | When the “all OK” text does NOT appear (e.g. All Systems Operational) · when a problem text appears (e.g. Major Outage | Degraded) · when the page changes compared with the first reading. Multiple alternatives separated by |, case-insensitive. |
| RSS feed | When there is news more recent than the chosen period (from 1 hour to 1 week). While the feed is “empty” it does not even appear in the scrolling ticker; when it becomes active the news scrolls in the ticker and, if chosen, goes full screen on the monitor. |
| X account | When the account publishes posts more recent than the chosen period. |

…/api/v2/status.json of Statuspage pages).
The X account type shows the recent posts of a public account full screen, as slowly scrolling cards (new ones highlighted). With Watched it appears only when the account posts something: ideal for status accounts such as @MSFT365Status.
WallStatus reads the posts from X's public embeddable timeline, at most every 5 minutes per account. However, X often limits these requests (“rate limit reached”) and may return few posts or not the most recent ones. For a reliable check, enter an alternative feed for the same account (a self-hosted RSSHub, a Nitter instance, a service such as rss.app) or, if the service has a status page with RSS, use that directly as an RSS feed.

| Field | Meaning |
|---|---|
| Name | Name shown in the panel |
| Refresh every | How many seconds between reloads of the content item. 0 = never. Examples: 60 for a webcam, 300 for a dashboard, 0 for a live stream (reloading would interrupt it) |
| Duration in rotation | How many seconds it stays visible on rotating monitors. 0 = use the time set on the monitor (for Documents: 0 = until all pages have been shown) |
| Zoom | Enlarges (e.g. 150%) or reduces (e.g. 75%) the page. Useful for dashboards designed for small screens shown on large TVs |
| Scaling | Images and videos: Whole (with black bars), Fill (crops the edges), Stretch |
| Audio on | YouTube, HLS and videos start without audio; turn it on if the wall has speakers |
| Active | If off, the content item is skipped everywhere |
| Automatically accept cookies and consent screens | On by default: WallStatus automatically clicks "Accept all" on cookie banners and consent screens (YouTube/Google, Facebook, news sites and the most common consent platforms). Turn it off if a site should keep only the necessary choices |
| Preview | Opens the content item in a new tab to check the address |
The Web page type also accepts HTML pages saved in a file on the PC or in a shared network folder, for example a monitoring page generated by another system. In the Address field you can write the path in one of these ways:
| Form | Example |
|---|---|
| file:// address (as in the browser bar) | file://sed-sql-fs.atahotels.it/Dati/Sede/Sistemi%20Informativi/cbwallmonitor/una_cyberbox_wallmonitor.html |
| Windows network path | \\sed-sql-fs.atahotels.it\Dati\Sede\Sistemi Informativi\cbwallmonitor\una_cyberbox_wallmonitor.html |
| File on the wall PC | C:\Wall\pagina.html or file:///C:/Wall/pagina.html |
WallStatus saves the path as a file:// address (spaces become %20).
DOMAIN\user) and Password: WallStatus connects the share for the current Windows session (like net use, without saving it permanently).smb://server/share); WallStatus then finds it in /Volumes.The Documents type also accepts network files and folders: in the Document addresses (e.g. \\server\Dati\Bacheca\turni.pdf) and in the Folder field (e.g. \\server\Dati\Bacheca), with the same optional credentials.
For web pages that require a sign-in you can save a username and password: WallStatus enters them automatically when the login page appears, even after the session expires.
| Option | Effect |
|---|---|
| Username / e-mail | Username or e-mail address of the account |
| Password | Stored encrypted. Leave empty to keep it unchanged |
| Fill in automatically | Fills in the username and password fields when they appear. It also recognises two-step logins (first the e-mail, then the password), such as Microsoft 365 |
| Press "Sign in" | After filling in, it presses the sign-in button. It also answers "Yes" to Microsoft's "Stay signed in?" |
| HTTP authentication | For websites that show the browser's small "Sign in" system dialog (Basic/NTLM), typical of routers, NAS, cameras and old intranets |
| Delete the saved password | Deletes the stored password |
If the website usernames and passwords are already saved in Chrome or Edge, you can import them instead of retyping them. WallStatus does not read the browser's passwords directly (they are protected, and a program that did so would be blocked by antivirus software): the browser's official export is used instead.

chrome://password-manager/settings → Export passwords. Edge: edge://wallet/passwords → … → Export passwords. The browser asks for the Windows (or Mac) password and saves a CSV file.| Field | When it is needed |
|---|---|
| Domains allowed | Limits entry of the credentials to these domains, separated by commas (e.g. miosito.it, login.microsoftonline.com). Recommended: it prevents the password from being entered on a different website |
| Selectors | If automatic field recognition does not work on a particular website, enter the CSS selectors of the username field, the password field and the button (e.g. #username) |
| JavaScript | Code run every time the page loads, for example to close a cookie banner. For expert users only |
If the credentials are wrong, WallStatus suspends attempts for 10 minutes after 6 submissions, to prevent the account from being locked. This is recorded in the Log tab.
SMS codes, authenticator apps and smart cards cannot be automated. In these cases, do the first sign-in by hand directly on the wall (with mouse and keyboard): the wall browser keeps the session like a normal browser, and WallStatus keeps refreshing the page. For service accounts it is worth asking the IT administrator for a long-lasting session.
With the Online video type (or by pasting the link into a Web page) the video starts on its own in the full-screen player, without cookie consent screens: for YouTube WallStatus uses the "no cookie" version of the player. All the most common link formats are accepted:
https://www.youtube.com/watch?v=XXXXXXXXXXX https://youtu.be/XXXXXXXXXXX https://www.youtube.com/live/XXXXXXXXXXX https://www.youtube.com/channel/UCxxxxxxxxxxxxxxxxxxxxxx ← the channel's current live stream https://www.facebook.com/NomePagina/videos/1234567890/ ← public Facebook video or live stream https://fb.watch/xxxxxxx/ https://vimeo.com/123456789 https://www.twitch.tv/nomecanale ← Twitch channel live stream https://www.dailymotion.com/video/x8abcd1
The video starts on its own, without controls and without audio (can be enabled with Audio on). The channel link is useful for channels that broadcast recurring live streams: it always shows the current one. Leave Refresh every at 0. Some owners forbid playback outside their website: in that case "Video unavailable" appears. Facebook videos must be public.
Enter the stream address, which ends in .m3u8. Many IP cameras, NVRs, encoders (OBS, vMix, Wowza) and streaming platforms provide one. If the stream is interrupted, WallStatus automatically retries every 10 seconds.
For cameras use the dedicated Camera type (below): it also accepts HLS streams with the same options.
The Camera type shows video from surveillance cameras, NVRs and webcams full screen or in a grid tile. WallStatus recognises the type of stream from the address by itself:
| Mode | Example address | How it works |
|---|---|---|
| RTSP (also RTSPS, RTMP, SRT) | rtsp://192.168.1.64:554/Streaming/Channels/101 | The format of almost all IP cameras. WallStatus converts it for the browser with ffmpeg (see below): H.264 passes through without transcoding (low CPU), H.265 is transcoded automatically. Conversion runs only while the content item is on air. |
| MJPEG | http://192.168.1.64/axis-cgi/mjpg/video.cgi | Continuous stream of images, supported by many cameras and encoders; ffmpeg is not needed. |
| JPEG snapshot | http://192.168.1.64/ISAPI/Streaming/channels/101/picture | One image every Refresh every seconds (0 = every 2 s), replaced only when it is ready: no flicker. Light on the network. |
| HLS | https://…/live/index.m3u8 | Streams already prepared for the web (NVRs, go2rtc, Frigate, encoders). |
| USB webcam | webcam or webcam:Logitech | The webcam connected to the wall PC (the first one, or the one whose name contains the given text). Video only. |

user:password@, they are moved into the fields automatically.
ffmpeg is a free program. In the camera form, the panel shows whether it has been found. To install it:
winget install ffmpeg, or download the “essentials” build from ffmpeg.org and copy ffmpeg.exe next to WallStatus.exe (or into C:\ffmpeg\bin).brew install ffmpeg (Homebrew), or copy the ffmpeg file next to WallStatus.app.WallStatus finds it on its own, without a restart (within a minute). Video encoding: Automatic (recommended), Pass through without transcoding (minimum CPU use) or Always transcode to H.264 (for cameras with unusual streams; uses more CPU, maximum 1920 pixels wide).
Upload an mp4 or webm file (up to 200 MB) or enter an address. The video plays in a loop.
Paste the link to the live event, town hall or meeting, exactly as it arrives in the invitation. WallStatus opens the web version of Teams and automatically tries to:
The wall's camera and microphone are always blocked: the wall can only watch and listen.
The Documents content type shows static files (PDF, Word, Excel, PowerPoint, images, text) page by page, changing page every few seconds. A single content item can gather several documents, which are shown one after the other.


| Format | How it is shown |
|---|---|
| Page by page, sharp at any resolution. Password-protected PDFs too (see below). | |
| Word (.docx) | Page by page, with the page breaks saved by Word. For an appearance identical to the original, enable conversion to PDF. |
| Excel (.xlsx, .xlsm, .xls, .ods, .csv) | One sheet per page, as a table (up to 400 rows and 60 columns per sheet). Tall sheets scroll in steps. |
| Images (jpg, png, gif, webp, svg, bmp) | Whole, centred on the screen |
| Text (.txt) | As a page of text |
| PowerPoint (.pptx, .ppt, .ppsx), .doc, .rtf, .odt, .odp | Converted automatically to PDF: requires LibreOffice (free, libreoffice.org, Windows and Mac) or Microsoft Office (Windows only) installed on the wall PC. Without a converter a warning appears: alternatively, save the file as PDF. |
C:\Bacheca or a network folder such as \\server\Dati\Bacheca. All the documents in the folder are shown in name order; added, changed or removed ones are detected automatically (within a minute or the Refresh every time).| Option | Meaning |
|---|---|
| Change page every | Seconds for each page (minimum 3, default 10) |
| Whole page | Each page is shown in full, as large as possible |
| 2 pages side by side | Two portrait pages next to each other: ideal for A4 documents on 16:9 screens |
| Screen width | The page fills the whole width and scrolls from top to bottom in steps: larger text, suitable for long documents |
| Convert Word and Excel to PDF | With LibreOffice or Microsoft Office: appearance identical to the printout (fonts, headers, charts). The panel shows which converter was found. |
| Refresh every | How often to download the web addresses again (0 = every 5 minutes) |
| Duration in rotation | 0 = the monitor moves to the next content item only after the last page of the last document; a number of seconds limits it |
Headlines from one or more RSS feeds can scroll in a bar at the bottom (or top) of any monitor, over web pages, grids, images and live streams.
The bar appears within a few seconds, without reloading the pages. To remove it press ✕ next to the feed; to suspend it on all monitors, turn off the RSS feed content item in the Content tab.
With Single continuous strip across all monitors enabled (the default), the monitors that have feeds form a single bar: the text enters from the rightmost monitor, leaves its left edge and enters the next monitor, as if the wall were a single screen. News from all the monitors' feeds is put in sequence, the bar height is the same everywhere and the feed label appears only on the first monitor on the left.
The text scrolls from right to left across the three screens without interruption.
The position of the screens is the one detected by the operating system (from left to right): if the text "jumps" between two monitors, check in the display settings that the arrangement matches the real one, then press Detect screens. Disabling the option gives each monitor its own bar again, with its own feeds, position and speed.
On mobile and in the web view (chapter 16) all the monitors' feeds scroll in sequence in a single bar at the bottom of the page, whichever monitor you are viewing; the wall bar is removed from the image so you do not see it twice.
https://www.ansa.it/sito/ansait_rss.xml). Google News creates feeds on any topic: https://news.google.com/rss/search?q=argomento&hl=it&gl=IT&ceid=IT:ithttps://www.githubstatus.com/history.rss).To alert people watching the wall to something important: a message appears in the centre of the chosen monitors, above any content and above the scrolling ticker, until it expires or is removed. It is written from the panel or from a hidden page on your website, reachable from your phone even outside the office.
With several active messages on the same monitor, up to 3 are shown, the most important first. Each send and each removal is recorded in the Log with the user's name; messages stay active even if WallStatus is restarted.

If the panel cannot be reached (closed internal network, you are out of the office), messages can be left on a page published on your website with Cloudflare and protected by a random token: whoever has the link enters their name, the priority and the text, and chooses the monitors and the duration. WallStatus reads the page as an RSS feed every 15 seconds–5 minutes: the connection goes from the wall PC to the Internet (even via a proxy, chapter 19), so no ports need to be opened towards the PC.

wallstatus).wallstatus-worker.js script (in the Windows package, or from the link in the Messages tab) and press Deploy.WS.TOKEN, paste the token.tuosito.it/avvisi/*, or a subdomain.https://tuosito.it/avvisi), enable it, Save and press Test now.Cloudflare's free plan is enough.
Messages arriving from the website appear in the Messages tab list with the label from the website and the name of whoever wrote them; removing them from the panel also makes them disappear from the page. The page receives from WallStatus only the names of the active monitors, to offer them as choices.
TOKEN secret: the old link stops working immediately.The Servers tab continuously checks servers, services and network resources, sends a notification when something goes wrong and when it is back to normal, and creates status screens to show on the monitors like any other content.
| Check | What to enter | Result and thresholds |
|---|---|---|
| Ping | Host or IP address | Red if it does not respond; optional yellow/red above a latency (ms) |
| TCP port | Host and port | Red if the port is closed |
| Website | Address; text that must appear (optional); HTTP username and password | Red on HTTP error or missing text; thresholds on response time |
| SSL certificate | Host (port 443) | Yellow if it expires within 30 days, red within 7 (adjustable) or if expired; warning if untrusted |
| DNS | Name to resolve; optional expected IP and DNS server | Red if it does not resolve or resolves to a different IP |
| Network folder | Path \\server\cartella or file; optional username and password | Red if it is not reachable or readable |
| File freshness | File or folder (with filter, e.g. *.bak) | Checks the most recent file: yellow over 26 hours, red over 48 (adjustable). Ideal for backups |
| Disk space | Disk or path (C:) | Yellow below 20% free, red below 10% |
| CPU / RAM | — (wall PC) | Yellow above 85% used, red above 95% |
| Windows service | Service name (e.g. Spooler) | Red if not running; optional automatic restart |
| Process | Process name (e.g. programma.exe) and start command | Red if not running; optional automatic restart |
| Event log | Log (System, Application) and minutes to consider | Counts the errors: yellow from 1, red from 10 (adjustable) |
| FTP/FTPS, SSH/SFTP | Host and port | Red if the server does not respond with its welcome message |
| SQL Server | Host and port (1433) | Red if the database port does not respond |
Windows services, event logs and service restarts work only on Windows; to restart a service WallStatus must have administrator rights. Checks cover what the wall PC can reach on the network: CPU, RAM, disks, services and processes are those of the PC itself (or of reachable shared disks and folders).

Notifications… button in the Servers tab. Notifications are sent when a check changes to Problem and when it returns to OK (optionally also for yellow warnings).
| Channel | What is needed |
|---|---|
| Pushover | User key and API token. Two accounts: standard and critical; checks with emergency priority use the critical one, which rings even with the phone on silent and repeats the alert until it is acknowledged |
| SMTP server, port, security (STARTTLS or TLS), username and password, sender and recipients (one per line) | |
| Telegram | Bot token and one or more Chat IDs |
With No notifications in the first minutes after startup you avoid false alarms when the PC restarts and the services have not started yet. The Test buttons send a test message on each channel. Tokens and passwords are stored encrypted.
The History button lists the events (problems, recoveries, automatic restarts, notifications not sent), which can be filtered by check. The history is saved in the data folder (monitor\storico.jsonl).
With + New screen choose the name, the checks to show (none = all), the columns (0 = automatic) and whether to show only checks with problems (when everything is fine, "All OK" appears). Each screen automatically becomes the Server · name content item: in the Monitors tab add it to a monitor like a web page, even in rotation or in a grid. Preview opens it in the browser.
The Bandwidth tab reads the traffic of network devices (Cyberbox, routers, firewalls), calculates download and upload in Mbps and the usage relative to the line bandwidth, pings them and shows the charts in screens to be assigned to the monitors. The border of each chart turns yellow or red when the bandwidth in use exceeds the thresholds.
| Mode | How it works and what is needed |
|---|---|
| Direct SNMP | WallStatus queries the device via SNMP (v2c or v1) from the wall PC. SNMP must be enabled on the device, with the given community, and the wall PC's IP must be among the authorised ones. Nothing needs to be installed. |
| SNMP via SSH host | For devices reachable via SNMP only from another network: WallStatus connects via SSH to a Linux server on that network (bridge host, in Settings), which makes the SNMP requests with snmpbulkwalk (net-snmp package). |
| SSH | For devices with a real Linux shell: WallStatus connects via SSH and reads /proc/net/dev, without SNMP. It does not work with the proprietary consoles of many routers and firewalls. |
Settings… button: reading interval (default 30 s), timeout, general thresholds, ping at every reading, hide interfaces with no traffic, saving to CSV (one file per month in banda in the data folder, can be opened with Excel) and the SSH bridge host details.

With + New screen choose the name, devices (none = all), period shown in the charts (from 15 minutes to 6 hours) and columns. Each screen becomes the Bandwidth · name content item to add to a monitor. One chart for each interface shown, with current values, percentages and ping result.
A screen with the map of Italy: each site is a dot coloured according to the ping result, and the links between sites show flowing packets. At a glance you can see which branch is not responding or is slow.

| Element | Meaning |
|---|---|
| ● dot | Site or branch. ■ square: data centre or cloud service. Double circle: the wall site. |
| Colour | Green responds below the yellow threshold (default 80 ms) · yellow slow or one ping lost · red no response for 2 pings in a row or above the red threshold (250 ms) · light blue site without an address (position only) · grey waiting. |
| Link | Takes the colour of the worse of the two sites. The dots flow continuously, more slowly when latency is high; at each ping round a “packet” goes from one site to the other and back (echo), while a wave spreads out from the checked sites. When a site does not respond, the link becomes red and dashed and the packets stop. |
| Labels | Site name and latency (or ✕); they are arranged so as not to overlap. Sites outside Italy (e.g. a data centre in Frankfurt) widen the map to include them. |


10.20.1.1), reachable from the wall PC. With Test the ping you check it immediately. Empty = the site appears on the map without checks (useful for headquarters).Import from Bandwidth/Servers creates sites in one go from the devices in the Bandwidth tab and the Ping checks in the Servers tab (they must then be positioned: they are flagged “to be positioned”). Location from public IP derives the approximate city of a public IP address via the free ip-api.com service (it asks for confirmation before sending it); for internal network addresses (10.x, 192.168.x…) the position must be chosen by hand.
Via Recanati, 26, 98035 Giardini Naxos ME, and press Find address (or Enter). Latitude, longitude and place are filled in automatically and the map zooms in on the point found. If the street is not found, the site is placed on the town (approximate position, flagged): you can correct it with a click on the map. The search uses the public OpenStreetMap Nominatim service: on the first search WallStatus asks for confirmation before sending the address. The address is saved with the site and shown in the list.+ New link: choose the two sites (From and To), the type (Fibre, VPN, MPLS, Radio link, Other) and an optional label written along the line (e.g. “Fibre 1 Gbps”).
With Link all the other sites to “From” you create a star topology in one step: all branches linked to headquarters. Links are removed with ✕ and are removed automatically when you delete a site.


+ New screen: each screen becomes the Map · name content item to be assigned to a monitor from the Monitors tab, even in a grid or in rotation. Options:
With Preview ↗ you open it in a browser tab.
Settings… button: ping every N seconds (default 10), response timeout (2 s), pings lost in a row before red (2), yellow and red latency thresholds in milliseconds. The most important status changes (site not responding, reachable again) go into the Log. To also receive notifications (Pushover, E-mail, Telegram), add the same sites as Ping checks in the Servers tab.
From a smartphone (or tablet) you can see what each wall monitor is showing: the screens pass in rotation, with the image updated every 3 seconds.



http://192.168.1.50:8088/mobile.| Control | Function |
|---|---|
| ‹ › or swipe | Previous / next monitor |
| ❚❚ / ▶ or tap on the image | Pauses or resumes the rotation |
| 5 s … 60 s | Time each monitor stays on screen (remembered by the phone) |
| ▦ | Shows all monitors together as thumbnails; tap a thumbnail to open it |
| Dots at the bottom | One dot per monitor: tap to go straight to that monitor |
| ⚙ | Opens the panel (only for users with at least one management permission) |
| Sign out | Closes the session on the phone |
On iPhone: Safari → Share → Add to Home Screen. On Android: Chrome → ⋮ menu → Add to Home screen. WallStatus opens full screen with its own icon. Turning the phone to landscape makes the image fill the whole screen.
What each monitor shows on the HDMI (or DisplayPort) cable can be watched live in any browser on the network: useful on a second screen in the control room, on a smart TV or on the PC of whoever supervises the wall.
| Address | What it shows |
|---|---|
http://<wall-address>:8088/Monitor01 | The first monitor in the Monitors tab (/Monitor02 the second and so on, including virtual monitors). The number is the one in the small square next to the monitor name; each monitor card also has the Web view link. |
http://<wall-address>:8088/Reception | The monitor you gave the Name in the link «Reception» (chapter 6) |
http://<wall-address>:8088/Monitor | All active monitors in rotation, as on mobile (10 seconds each; to change it add for example ?t=20 to the address) |
The full addresses are listed in Settings → Network and mobile access. The image is live (up to about 8 frames per second, audio is not transmitted) and is captured only while someone is watching.
As for the mobile view, network access must be enabled and you need a user with the View streams permission (chapter 17): they see only the monitors assigned to them, and only within their validity period. With Remember on this device the sign-in lasts 30 days. For screens without a keyboard, such as a smart TV, you can enable Monitor view without password in Settings: anyone on the network will be able to watch /Monitor and /mobile, but not change anything.
| Control | Function |
|---|---|
| Double-click or F key | Full screen |
| 🖱 Control | Remote control of the monitor (see below, only users with the Displays permission) |
| ← → or dots at the top right | Previous / next monitor (in /Monitor) |
| Space | Pause / resume rotation |
| 🎧 Listen here | Plays the audio of the content on air (videos, live streams, cameras) in your browser: it appears if the monitor has audio set to “In the web view” or “Both” |
| Audio menu | For users with the Displays permission: chooses where the monitor's audio plays (wall, web view, both) |

The audio is played directly in your browser from the source (YouTube, HLS stream, camera, video): it may be a few seconds ahead of or behind the image. Generic web pages have no audio to listen to here.
From the web view (/Monitor01, /Reception…) users with the Displays permission can interact with the page shown by the monitor, from their own PC or phone: this is useful, for example, for the first sign-in to Facebook or a website with two-step verification, closing a notice or choosing an option, without going to the wall.

The image updates live, so you see the effect immediately. The Log records who used remote control and when, never the text typed (it may contain passwords). It also works on virtual monitors.
In the Users tab (visible only to administrators) you create the accounts of those who manage the wall and those who only need to watch the monitor streams. For each one you choose what they can do, which monitors they can see and how long the account is valid.
| Permission | What it allows |
|---|---|
| Administrator | Everything, including the Users tab (creating, editing, disabling and deleting users). Includes all the other permissions. Can reset the password of any user, including other administrators. |
| Monitors | Monitors tab: layouts, assigned content, physical screen, scrolling ticker |
| Content | Content tab: add, edit, enable and delete content, upload files and documents |
| Displays | Start/Stop displays, Reload, Identify, Detect screens, Restart displays |
| Settings | Startup, displays, network access, browser, ports, closing WallStatus |
| Log | Log tab with recent events. Each line shows the user who did the operation; the last 30 days are kept. |
| Messages | Messages tab: send and remove messages on the monitors and see the link to the page on the website (chapter 12) |
| Monitoring | Servers and Bandwidth tabs: checks, notifications, devices and screens (chapters 13 and 14) |
| View streams | Browser view (/Monitor, /Monitor01…) and mobile view (/mobile), limited to the chosen monitors |
The panel shows each user only the tabs and buttons they are allowed; WallStatus checks permissions on every operation anyway. Those with only View streams are taken straight to the mobile view. Every user, whatever their permissions, can change their own password in Settings → My account.
/MonitorNN addresses show as not available. It can also be done the other way round, from the monitor's card: Who can see it (chapter 6).It works as in Microsoft Active Directory: the administrator assigns a temporary password and the user, at first sign-in, must replace it with one of their own.
There must always be at least one active administrator with no expiry date: WallStatus does not allow it to be disabled, made to expire or deleted, and nobody can delete their own account. If the administrator password is forgotten, see chapter 21.
| Need | User to create |
|---|---|
| Control room smart TV showing the wall | Only View streams, all monitors, no expiry; on the TV open /Monitor and sign in with Remember on this device |
| Department manager who follows only their monitor from their phone | Only View streams, only the department's monitor |
| External supplier for an event | Only View streams, expiring at the end of the event |
| Communications office updating notices and documents | Content manager preset |
| Duty technician who restarts the displays | Operator preset |
| Intern for three months | Necessary permissions, 3 months button in the validity |
When updating from a previous version, the administrator account and any "view only" account are converted automatically into users, with the same passwords.
| Setting | Description |
|---|---|
| Start at power-on | Starts WallStatus automatically when the user signs in |
| Open the displays at startup | If off, only the panel opens at startup |
| Delay on automatic start | Seconds to wait after power-on, to give the network time to connect (default 8) |
| Hide the pointer when idle | Hides the mouse arrow after 4 seconds of inactivity; as soon as you move the mouse it reappears, so you can click (for example on a screen to accept) |
| Prevent the screen from turning off | Keeps the screen on and prevents standby |
| Restart the displays | If the browser closes or freezes, WallStatus reopens it on its own |
| Browser | Leave empty for automatic detection; or enter the path of a specific browser |
| Monitor view without password | Lets anyone on the network watch the web view and the mobile view without signing in (view only). Off by default |
| Key combinations | Close the displays and open the panel (default Ctrl+Alt+Shift+A) and Force close (default Ctrl+Alt+Shift+Q), in the Keyboard shortcuts on the wall box (chapter 20) |
| Internet proxy | Proxy for RSS feeds and messages from the website; empty = the Windows one (chapter 19) |
| Port switcher | Remote Desktop, panel and other applications on the same port (Windows only, administrators only, chapter 19) |
| Panel port | Default 8088. Change it only if it is already used by another program (takes effect at restart) |
Every user can update their own name and change their own password: Settings → My account → new password → current password → Save. Changing the password closes open sessions on other devices. Username, permissions and expiry are changed by an administrator in the Users tab (chapter 17). If an administrator has required a password change, the new password must be chosen right after signing in (chapter 17).
http://192.168.1.50:8088/admin, together with the mobile view QR code.Access to the web view and the mobile view is granted by creating users with the View streams permission in the Users tab (chapter 17), with the desired visible monitors and expiry. Alternatively, for the internal network only, Monitor view without password opens viewing to everyone.
Ask IT to give the wall PC a fixed IP address (or a DHCP reservation), so the panel and mobile view addresses do not change.
After 5 failed sign-in attempts in 5 minutes, sign-in from that address is temporarily suspended; failed attempts are recorded in the Log. When network access is disabled, the panel and mobile view can again be reached only from the wall PC. The Log also records successful sign-ins, those refused because of an expired or disabled account, and changes to users.
WallStatus is available in Italian, English, Spanish, German, French, Russian, Chinese, Japanese and Arabic (Arabic with right-to-left script).

Each language is an XML file. Each text appears twice: <source> with the Italian original and <text> with the translation:
<language code="pt" name="Portoghese" native="Português" dir="ltr" locale="pt-PT"> <string id="3f9a1c20"><source>Monitor salvati</source><text>Monitores guardados</text></string> … </language>
<text>. Leave <source>, the {0}, {1}… placeholders and the <b>, <code>, <kbd> tags unchanged. For a new language set the attributes code (e.g. pt), native (the name in the language itself), dir (rtl for right-to-left languages) and locale.Uploaded languages stay in the data folder (lang) even after updates; Delete returns to the translation built into the program. When a new version adds texts, Download XML inserts them at the end, empty, with the note «da tradurre» (to be translated). The event log stays in Italian.



Close WallStatus (Settings → Advanced) turns off the displays and ends the program; on the wall PC you can also use the force close key combination (chapter 20). To restart it use the shortcut on the Desktop or in the Start menu (Windows) or the app in Applications (Mac), or restart the computer if automatic start is enabled.
When the wall PC can be reached from the network on a single port (typically Remote Desktop's 3389), the switcher lets you use it for several services: it recognises the type of connection and routes it to Remote Desktop, the WallStatus panel or another application. Windows only, administrators only.
address:port or Reject. So in future you can route the port to another application without touching anything else.
http://127.0.0.1:8088/admin: installation and uninstallation ask for administrator rights with a Windows dialog on the PC screen.http://<wall address>:3389/admin (requires Allow access from other PCs and phones on the network, chapter 18).The service uses a copy of the program in %ProgramData%\WallStatus\gateway: WallStatus updates do not touch it and Remote Desktop always stays reachable. To bring the switcher up to the new version too, press Update the switcher from the panel on the PC (the port closes for a few seconds, Remote Desktop stays on the internal port). Uninstall the switcher stops the service, returns Remote Desktop to its original port and closes the port in Windows Firewall. The Switcher events section shows the latest operations (changes, confirmations, rollbacks, errors).
RSS feeds and messages from the website (chapter 12) are read by the wall PC. If the network reaches the Internet through a proxy: Settings → Advanced → Internet proxy.
| Value | Meaning |
|---|---|
| empty | Uses the Windows proxy settings, like the browser: Automatically detect settings (WPAD, wpad.dat file), Use setup script (PAC file) and Manual proxy setup |
none | No proxy: direct connection |
http://proxy.azienda.it:8080 | Proxy entered by hand; with username and password: http://utente:password@proxy.azienda.it:8080 |
With automatic configuration (WPAD or PAC script) Windows itself works out the proxy for each address: WallStatus reaches the Internet exactly like Edge and Chrome, without you having to enter anything. If the script cannot be found or does not respond, WallStatus uses the manual configuration proxy, if there is one. Automatic proxy sign-in with the Windows user (NTLM/Kerberos) is not supported: if the proxy asks for authentication, put username and password in the proxy address or ask IT to allow your domain without authentication. The Messages tab shows the settings read from Windows, the proxy chosen and the error from the last attempt.
They work with a keyboard connected to the wall PC, while the displays are visible (on a Mac always use the Ctrl key, not ⌘).
| Keys | Action |
|---|---|
| Ctrl+Shift+A | Opens the admin panel in a new window |
| Ctrl+Shift+N | Moves to the next content item (rotating monitors) |
| Ctrl+Shift+P | Goes back to the previous content item |
| Ctrl+Shift+Space or S | Pauses / resumes the monitor's rotation |
| PgDn / PgUp | Next / previous content item on rotating monitors (presentation remotes) |
| ⏭ ⏮ ⏯ | Media keys: next, previous, pause / resume |
| Ctrl+Shift+R | Reloads all monitors |
| Ctrl+Shift+I | Identifies the monitors |
| Ctrl+Shift+Q | Closes the displays (the panel stays available to reopen them) |
| Ctrl+Alt+Shift+A Mac: Control+Option+Shift+A | Closes the displays and opens the panel in the browser: WallStatus stays running (can be changed, see below) |
| Ctrl+Alt+Shift+Q Mac: Control+Option+Shift+Q | Force closes WallStatus: displays and program (can be changed, see below) |
Two key combinations let you work on the wall PC without a mouse or the panel:
| Combination | What it does |
|---|---|
| Ctrl+Alt+Shift+A Mac: Control+Option+Shift+A | Closes the displays and opens the panel. The full-screen windows close, WallStatus keeps running and the web configuration (http://127.0.0.1:8088/admin) opens in the default browser. To turn the displays back on: Start displays button in the panel. This is the combination to use to configure the wall from the PC itself. |
| Ctrl+Alt+Shift+Q Mac: Control+Option+Shift+Q | Force closes WallStatus: displays and program. If the orderly shutdown does not finish within 10 seconds, WallStatus closes the wall browser anyway and exits. To restart it use the shortcut on the Desktop or in the Start menu (Windows), the app in Applications (Mac) or restart the PC if automatic start is enabled. |
| System | When they work |
|---|---|
| Windows | Always, whichever window is in the foreground (they are registered as system shortcuts), even if the wall browser is not responding. If another program already uses the same combination, the Log reports it: in that case it works only on the wall monitors, or choose another one. |
| Mac | When a wall monitor is in the foreground (click on a wall screen, then the combination). A system-wide shortcut would require granting WallStatus macOS Accessibility permissions. |
To change them (Settings permission required): Settings → Keyboard shortcuts on the wall → Change… next to the combination → press the new combination (Esc cancels). At least two keys among Ctrl, Alt/Option and Shift plus a letter, a digit or a key from F1 to F12 are allowed; with an F key a single modifier is enough (e.g. Shift+F12). The two combinations must differ from each other and from the other shortcuts. Default restores the original one; Disable removes it. Changes take effect immediately, without restarting.
You can connect to the wall PC with Remote Desktop (Windows 11 Pro/Enterprise) to configure it or work on it. Connect with the same user the wall runs as: that way you find WallStatus running and the key combinations work from the remote session too (the Windows Remote Desktop client does not intercept Ctrl+Alt+Shift+A and Ctrl+Alt+Shift+Q). With a different user another session opens, in which WallStatus is not running.
| When | What happens and what to do |
|---|---|
| During the connection | Windows moves the session to the PC you are connecting from: the wall monitors show the lock screen and the WallStatus windows move to your screen. To configure, use Ctrl+Alt+Shift+A (or the Chiudi i display e apri il pannello shortcut), or open the panel with the WallStatus – solo pannello shortcut. |
| To disconnect | Double-click Torna al wall (chiudi Desktop remoto) on the Desktop (or in the Start menu) and confirm the administrator prompt: the remote connection closes and the session returns to the wall screens. WallStatus notices within a few seconds, detects the screens and puts each window back on its monitor. |
| If you close the Remote Desktop window without using Torna al wall | The session stays disconnected and the wall monitors stay on the lock screen until someone signs in from the wall PC keyboard (or you reconnect and use Torna al wall). |
Useful shortcuts, in the Start menu → WallStatus, which also work without a keyboard (for example from a remote client that does not transmit key combinations):
| Shortcut | Effect |
|---|---|
| Chiudi i display e apri il pannello | Like Ctrl+Alt+Shift+A: turns off the screens, WallStatus keeps running and the panel opens. If WallStatus is not running, it starts it with the panel only. |
| Chiudi WallStatus | Like Ctrl+Alt+Shift+Q: closes displays and program. |
| Torna al wall (chiudi Desktop remoto) | Returns the session to the wall screens and closes the remote connection. Requires an administrator account. |
From a Mac with the Windows App (formerly Microsoft Remote Desktop) the Control, Option and Shift keys correspond to Ctrl, Alt and Shift; if a combination does not get through, use the shortcuts above.
A single monitor with the 2 side by side layout and the two content items in left → right order.
Monitor with the Rotation layout, Change content item every 20 seconds, with for example: welcome page, image with notices, weather, YouTube live stream. To give one content item more time, set its Duration in rotation.
Create an RSS feed content item and add it in the Scrolling ticker section of each monitor: with the single strip enabled, the text crosses the whole wall. For an urgent notice you can use the feed of a SharePoint list or an internal blog.
Documents content item with the shared folder where the manager saves shift rotas (PDF) and indicators (Excel), 2 pages side by side, a page every 15 seconds. Assign it to a Single monitor, or in Rotation together with the production dashboard.
Open http://<wall-address>:8088/Monitor in the screen's browser and press F: the wall monitors alternate live.
Settings → enable network access → scan the QR code. With automatic rotation you see the status of all monitors in a few seconds.
Content → turn off the content item's switch. It is skipped on all monitors; turn it back on when needed.
For any problem, first look at the panel's Log tab: it shows recent events (browser start, screens detected, automatic sign-ins, errors).
Every operation done from the panel (content, monitors, settings, users, sites, messages…) appears with [user] after the date and time, so you always know who did what; program events (start, browser, checks) have no user. At the top you can filter by user and by text. The log keeps the events of the last 30 days: older ones are deleted automatically (at start and then every hour).
| Problem | Solution |
|---|---|
| Nothing appears at startup | Open http://127.0.0.1:8088/admin on the wall PC and read the red message. The most common case on the Mac is that Chrome or Edge is missing. |
| "No compatible browser found" | Windows: check that Microsoft Edge is present. Mac: install Google Chrome. If the browser is in a non-standard path, enter it in Settings → Browser. |
| A monitor stays black or shows its content on the wrong screen | Panel → Detect screens, then Identify and correct the Physical screen. Check the screen arrangement in the operating system settings. |
| Warning "physical screen N is not connected" | The screen is off or disconnected. Switch it on and press Detect screens. |
| On the Mac only one monitor goes full screen | Turn on "Displays have separate Spaces" (chapter 4) and sign out and back in to the user. |
| A grid tile is empty or shows an error | Test the content item with Preview. If it is a website with login, use it on a Single or Rotation monitor. |
| Automatic sign-in does not work | Check username and password; read the Log (after 6 attempts it is suspended for 10 minutes). For particular websites fill in the Selectors in the advanced options. With two-step verification the sign-in must be done by hand the first time. |
| "Site not reachable" page | WallStatus retries automatically every 20 seconds. If the network comes up late at power-on, increase Delay on automatic start. |
| An RTSP camera stays black or says “ffmpeg not found” | Install ffmpeg (chapter 9) and wait a minute. Then open the content item and press Check the camera: the message tells you whether the problem is the password, the stream path or reachability. For the exact address use the guided set-up or the camera manual. |
| Camera: “incorrect username or password” | Check the credentials; some brands require a user dedicated to RTSP (Tapo, EZVIZ) or RTSP/ONVIF to be enabled in the camera settings (Reolink, EZVIZ). |
| All sites on the map are red | Check from the wall PC that ping works (Test the ping in the site). Often the sites' firewall or Windows Firewall blocks ICMP: allow ping or enter another device at the site. |
| The ⏮ ⏸ ⏭ buttons do not appear | They appear only on monitors in Timed or Manual rotation, with at least two active content items, displays running, and for users with the Displays permission. |
| The YouTube video says "unavailable" | Some owners forbid embedded playback, or the live stream has ended. Use the channel link for the current live stream, or the Web page type. |
| The panel does not open from my PC or phone | Check that network access is enabled (chapter 18), that the devices are on the same network (guest Wi-Fi is often isolated) and that Windows Firewall allows WallStatus on private networks. |
| The news bar does not appear | Check that the feed is active and assigned to the monitor; open the content item and press Test the feed. If the feed does not respond, the bar appears as soon as the first news arrives (it retries every minute). The Log reports feed errors. |
| Document: "requires LibreOffice or Microsoft Office" | PowerPoint, .doc, .rtf and OpenDocument must be converted: install LibreOffice (free) on the wall PC, or save the file as PDF. On Windows Microsoft Office also works. |
| Document: "access denied" or "web page instead of the document" | Check the content item's username and password. If the website uses a login page (SharePoint, OneDrive, portals), use a direct download link or a synced folder. |
| Word or Excel document looks different from the original | Enable Convert Word and Excel to PDF (requires LibreOffice or Office) or save the document as PDF. |
| The ticker strip is not continuous between two monitors | The screen arrangement in the operating system does not match the real one: correct it and press Detect screens. Check that the single strip is enabled. |
| A message does not appear on the monitor | Check in the Messages tab that it has not expired and that it is assigned to that monitor; with more than 3 active messages only the 3 most important are shown. The displays must be on. |
| Messages from the website: "the site responds 404" | The address is wrong or the WallStatus token does not match the worker's TOKEN secret: copy it again and press Test now. |
| Messages from the website: "site not reachable" or "not the message feed" | The wall PC cannot reach the Internet or the proxy blocks the address: enter the proxy in Settings → Advanced (chapter 19) and ask IT to allow your domain. "The proxy asks for username and password": put them in the proxy address. |
| Switcher: "port 3389 is not available" | Another program is using the port. If it is Remote Desktop, the switcher moves it only when a rule points to Remote Desktop: check the destinations and the internal port. |
| After enabling the switcher I can no longer connect via Remote Desktop | Wait for the trial minutes (5 if you have not changed them): without confirmation the switcher automatically reverts to the previous configuration and Remote Desktop returns to its original port. Then reconnect normally and look at Switcher events. |
| Web view black or frozen | The monitor is off, disconnected or the displays are stopped. If the network blocks the continuous stream, the page automatically switches to images updated every 2 seconds. |
| On mobile "This monitor is not displayed" | The monitor is active but its physical screen is not connected or the displays are stopped. |
| "Account expired" or "Account valid from…" | The user is outside their validity period: an administrator can change the dates in the Users tab. |
| "Your account does not have permission to…" | The permission for that function is missing: ask an administrator to add it. Those with only View streams cannot open the panel. |
| A monitor does not appear in the web view or on mobile | The monitor is not among the user's visible ones (Users tab → Visible monitors), the user is not among those chosen in the monitor's Who can see it, or the monitor is disabled. |
| Sound alerts cannot be heard | Audio tab: check that alerts are on, outside quiet hours, and test the sound with 🔊. Check the volume and mute of the default output (PC volume section) and, if audio comes from the TV, the TV volume. |
| The PC volume cannot be read (Windows) | The first time, WallStatus prepares the volume component (a few seconds). If PowerShell is blocked by company policy, volume control is not available: sound alerts still work. |
| The LG or Samsung TV does not respond | Press Pair and confirm on the TV within a minute; the TV must be on and on the same network. For LG enable “LG Connect Apps”, for Samsung allow the device in External Device Manager. |
| A watched content item never appears (or is always visible) | Open the content item and press Check now. Check the text searched for (it must appear in the page text, not in images) and, for pages built by scripts, use the RSS/JSON version of the status. |
| X account: “rate limit reached” or no posts | X limits reading without an account: enter an alternative feed for the same account (chapter 7) or use the service's status page as an RSS feed. |
| Traceroute: many hops with “no response” | Many routers do not respond to probes or respond only to some: this is normal. If the last hop responds, the destination is reachable. If no hop responds after the first, a company firewall is blocking the probes. |
| A scheduled content item does not start | Scheduling tab: check that it is active and that the time is the wall PC's time; the content item must be active. With several overlapping schedules on the same monitor, the first one in the list applies. |
| On mobile I have to sign in again | Sessions are closed when WallStatus restarts, when the user's password changes, when the account is disabled or expires, or when an administrator presses Disconnect. |
| I have forgotten the administrator password | On the wall PC: 1) close WallStatus (Windows: Task Manager → WallStatus → End task; Mac: Activity Monitor → WallStatus → Quit); 2) run the program with the --reset-password option (see chapter 22), which deletes the administrator users while leaving the other users, monitors and content intact; 3) restart WallStatus, open the panel from the wall PC and create a new administrator. If there is another administrator, they can simply reset the password from the Users tab. Network access is disabled and must be re-enabled. |
| Website passwords no longer work after copying the configuration to another PC | This is intentional: the encryption key is tied to the computer and the user. Re-enter the passwords on the new PC. |
| WallStatus is not responding or I need to free up the wall PC | Press Ctrl+Alt+Shift+Q (Mac: Control+Option+Shift+Q, with a wall monitor in the foreground) or the combination you set. As a last resort: Task Manager (Windows) or Activity Monitor (Mac) → WallStatus → End. |
| On Facebook (or another website) I need to enter username and password but cannot type on the wall | From the monitor's web view press 🖱 Control, click the field and type (chapter 16), or import the password from Chrome/Edge (chapter 8) and let automatic sign-in do it. On the wall PC: move the mouse, click in the field and type. |
| On the wall I cannot see the pointer and cannot click | Move the mouse: the pointer reappears for a few seconds. For cookie banners there is no need to click, if Automatically accept cookies and consent screens is on in the content item. |
| Page from a network folder: "File not reachable" | Open the same path in File Explorer from the wall PC with the wall user: if it asks for a password, enter Username (DOMAIN\user) and Password in the content item. Check that the path is complete and that the PC is connected to the company network (at startup too: increase Delay on automatic start). The Log reports the result of connecting to the share. |
| Page from a file displayed incompletely | If the page uses files outside its folder or absolute file:// addresses, enable Open directly as file:// (Single or Rotation monitors only). |
| I need to configure the wall but the displays cover the whole screen | Press Ctrl+Alt+Shift+A (Mac: Control+Option+Shift+A): the displays close and the panel opens. Then Start displays. |
| Only one screen is detected but there are two monitors | 1) Windows: Settings → System → Display → Extend these displays. 2) Panel → Detect screens. 3) Look in the Log for the schermi rilevati and rilevamento schermi dal browser lines: they show how many screens the browser and Windows see. Since version 1.5 the system list is used on Windows anyway. If the problem persists, send these Log lines to support. |
| After Remote Desktop the wall monitors show the lock screen | The session was left disconnected: reconnect with Remote Desktop and double-click Torna al wall (chiudi Desktop remoto), or sign in from the wall PC keyboard. To avoid this, always disconnect with that shortcut. |
| The close key combination does not work | Check in Settings which combination is set and that it is not disabled. On Windows the Log tells you if another program already uses it; on the Mac click on a wall screen first. |
| Displays start very slowly or windows are duplicated | Settings → Restart displays. WallStatus automatically closes any browser windows left open from a previous session. |
| System | Folder |
|---|---|
| Windows (installed) | %LOCALAPPDATA%\Programs\WallStatus\data |
| Windows (portable) | data subfolder next to WallStatus.exe |
| Mac | ~/Library/Application Support/WallStatus |
The exact path is also shown in Settings → Advanced. The folder contains:
| File / folder | Contents |
|---|---|
| config.json | Monitors, content, feeds, settings and users (passwords are encrypted or stored as a hash) |
| secret.key | Reference to the encryption key, protected by the operating system |
| media/ | Uploaded images, videos and documents |
| cache/ | Documents downloaded from web addresses and converted to PDF (it empties itself; it can be deleted while the program is closed) |
| browser/ | Wall browser profile (sessions, website cookies) |
| wallstatus.log | Event log (last 30 days) |
To save or replicate the configuration, copy config.json and the media folder while WallStatus is closed. On the new computer paste them into the data folder, start WallStatus and re-enter the website passwords (those encrypted on another PC are ignored).
For installations managed by scripts or deployment tools:
WallStatus.exe --no-display panel only, without opening the displays WallStatus.exe --data "D:\WallData" uses another data folder WallStatus.exe --install-autostart enables automatic start and exits WallStatus.exe --uninstall-autostart disables automatic start and exits WallStatus.exe --reset-password deletes the administrator users (to be recreated) WallStatus.exe --show-panel closes the displays and opens the panel (WallStatus keeps running) WallStatus.exe --quit closes the running WallStatus Windows (installed), from Win+R: "%LOCALAPPDATA%\Programs\WallStatus\WallStatus.exe" --reset-password Mac, from Terminal: /Applications/WallStatus.app/Contents/MacOS/WallStatus --reset-password
Show a content item full screen on a monitor at a precise date and time, every day or on certain days of the week: the midday news in the meeting room, a camera during an event, a presentation when visitors arrive. When the time slot ends, the monitor returns to its normal configuration.


The Audio tab (Displays permission; settings require the Settings permission) adjusts the volume of the PC and the TVs, manages the sounds and decides which events trigger a sound alert on the wall speakers.

To adjust the volume of the TV itself (not the PC) over the network. + Add TV: name, brand, IP address and, optionally, the wall monitor it corresponds to.
| Brand | Preparation | Commands |
|---|---|---|
| Sony Bravia | On the TV: Network → Home Network Setup → IP Control → Authentication “Normal and Pre-Shared Key”, choose a key and enter it in the PSK field. | exact volume, + / −, mute |
| LG webOS | Enable “LG Connect Apps” (or power on via network). Save, press Pair and confirm on the TV. | exact volume, + / −, mute |
| Samsung (Tizen) | Save, press Pair and choose Allow on the TV. | + / −, mute (no exact volume) |
| HTTP command | Addresses to call for each command ({v} = volume): Home Assistant, controllers, TVs with their own API. | those configured |
WallStatus includes 10 sounds: Bell, Notification, Alert (3 beeps), Alarm, Siren, Error, Recovery, Gong, Beep, Announcement. With Upload sound… you add your own (mp3, wav, ogg, m4a, up to 5 MB), for example a recorded announcement. For each sound: ▶ listen to it in your browser, 🔊 play it on the wall PC, ✕ delete uploaded ones. Sounds are used in alerts, messages and schedules.
For each monitor you can choose whether the audio of videos, live streams and cameras comes from the wall, from the browser of whoever is watching the web view, or both (chapters 6 and 16).
The Traceroute tab (Monitoring permission) shows the route packets take from the wall PC to an address: each router crossed (hop), the response time, the network it belongs to and its estimated position on a world map. Useful when a site or service is slow or unreachable, to understand where the route stops.


| Element | Meaning |
|---|---|
| Cards at the top | Hops detected, Last RTT (round-trip time of the last router that responded), Networks crossed (number of different ASNs), Hops with no response. |
| Route map | The probe (wall PC, in light blue) and the located hops joined by arcs; the colour shows the response time: green below 30 ms, yellow up to 120 ms, red above. The lines join estimated locations, not the actual cables. |
| Route | All hops in a row, from the PC to the destination (◎), with the time of each; “* * *” = no response. |
| Table | Hop · Device: role, address, DNS name and what is known about the device · Network and location: city, network (AS), organisation and network type · No response (unanswered probes out of 3) · Average RTT with minimum–maximum and bar. |
| Device role | Local gateway (your network's router), Internal network, Operator NAT, Your operator, Transit, Exchange (IXP), Destination network, Destination, Blocks traceroute (firewall). Below it you see: the device name if it is one of those configured in WallStatus (★); name and model read via SNMP for the devices in the Bandwidth tab; MAC address and manufacturer for devices on the local network; the other routers that answered the same hop; hints from the DNS name (backbone, border, customer link, load balancer) and from the network (datacenter, mobile network). |
| If the path stops | A box explains up to which hop the path is visible and why (for example a company firewall that does not let probes out to the Internet) and tests a TCP connection to the destination on ports 443 and 80: if it succeeds, the service is reachable even if it does not answer traceroute. |
tracert is used; on the Mac traceroute with ICMP probes and, if the path does not reach the destination, a second attempt with UDP probes (the one that gets further is kept). After 6 consecutive hops without an answer the trace stops. Finished traces can be viewed for two hours; those nobody is watching and that are not on a monitor stop by themselves.The Appearance tab (Settings permission) adapts WallStatus to the company's image: logo, name, fonts and all the colours of the panel, web view, mobile, monitor screens, messages and standby page. In addition: date and time on the monitors and the desktop wallpaper of the physical screens.

One font for the panel and views and one for the monitor screens (messages and clock included), chosen among the system fonts or the uploaded company font (woff2, woff, ttf, otf). The sample box shows the result immediately.
On external web pages shown by the monitors, messages and the clock use the company font only if it is also installed in the wall PC's system; otherwise they use the system font. On WallStatus pages (screens, standby page) it is always used.
#1e7fd0). With a light theme the form fields become light too.The colours of the scrolling ticker stay in the dedicated box in the Monitors tab (chapter 11).


This is the page shown by monitors with no active content and at startup: text of your choice (e.g. “Welcome”) instead of the technical message, optional background image, colours chosen among those of the screens.
Press Save appearance to apply identity, fonts, colours, standby page and clock: the monitor screens reload on their own with the new appearance. Restore defaults returns to the WallStatus appearance.
This manual is included in WallStatus: you always find it up to date with the version in use, even without Internet.

http://<wall-address>:8088/help, handy to keep open next to the panel./help/manuale.pdf).The same PDF is included in the installation packages for Windows and Mac.
Any PC on the network can show its screen on a wall monitor (virtual too) by opening a link in the browser. Nothing to install. It is a tab under test, visible only to administrators who have the Preview option.
/share, change it to something hard to guess), set a dedicated username and password, the destination monitor, the maximum duration and whether to allow audio.https://<wall-address>:8088/<path> with Chrome, Edge or Firefox on a computer, enters the username and password, presses Share screen and chooses the screen or window.The link is https because browsers only allow screen sharing from secure pages. WallStatus generates the certificate itself (valid 10 years, renewed automatically). The first time, each PC sees a warning: Advanced → Proceed, just once. To remove the warning entirely you can load a company certificate.
Sharing also works through the port switcher (chapter 19): HTTPS traffic is forwarded to the panel. The tab shows both the direct link and the one on the switcher's port.
The feature lets anyone with the password show anything on the enabled monitors. Keep it off when not needed, use a strong password, leave a maximum duration and enable only the monitors you want. Management is for administrators only.
Coming soon: a downloadable client (option B) for Windows and Mac, for PCs locked down by company policies that cannot share from the browser; it will not need administrator rights.
From the Settings tab you can update WallStatus by uploading the ZIP of the new version: WallStatus verifies it, keeps a backup, then closes and restarts updated. It is a tab under test, reserved for administrators with the Preview option.
WallStatus-<version>-update-windows.zip (or -mac.zip): it is small and contains only the program and a control file with the version and signature.Configuration, users, content, passwords and autostart stay as they are. A backup of the last three versions is kept in the data folder (update/backup), to roll back if needed.
Only upload official WallStatus update ZIPs: the signature check blocks corrupted or foreign files, but the update replaces the running program. The feature is reserved for administrators.